DAS Contact Form 7 Company Name Site Name Site Address or Coordinates Email Base Device Standard - Logger, Power Supply, Cellular Modem, 4X Enclosure, Online Monitoring Portal, Email Alerts ($4000) Inverter Type ChintSMA Include Flex Gateway (Required for Remote CPS Manufacturer FW Upgrades and Troubleshooting $1,075) Yes Gateways Needed (1 per 32 inverters) Include SMA Data Manager (Required for any Utility/Plant Control $1,175) Yes Gateways Needed (1 per 50 inverters) DAS Power Supply 120V Dedicated Line - Suggested ($75)480V Metering Tap ($0) LV Metering ($1050 per Meter with CTs) Yes Number of Transformers/Services to Meter MV Metering None ($0)Data Only from Existing Meter ($500)Data and Remote Control of Existing Recloser ($1000)MV Meter, CTs, PTs ($24000)MV Recloser, CTs, PTs ($28000) Connection Type Fiber ($150)Ethernet (only if within 330 ft) UPS None ($0)33 Wh Li-Ion - 500 Cycles, ~1 Hr Backup with Standard DAS, Sufficient to Trigger Email Alert and Upload Trip Files ($400)33 Wh LiFePo4 - 6,000 Cycles, ~1 Hr Backup with Standard DAS, Sufficient to Trigger Email Alert and Upload Trip Files ($550)1.1 Wh SuperCapacitor - >100k Cycles, ~9 Min Backup with Standard DAS, Sufficient to Trigger Email Alert ($800)0.1 Wh SuperCapacitor >100k cycles, ~1 Min Backup with Standard DAS, Sufficient to Trigger Email Alert ($300)192 Wh Sealed Lead Acid - 300 Cycles, ~6 Hr Backup with Standard DAS, Sufficient to Trigger Email Alert and Upload Trip Files ($350) Utility Interface None ($0)Duke Energy DGI ($2000)Pepco ($1500)Pacificorp ($0)First Energy ($1500)Ameren ($1500) Utility/Plant Control None ($0)Remote Trip ($800 + $200/yr)Export Limit ($1,600 + $400/yr)PPC Control ($3200 + $800/yr) Cameras ($450 + cameras) Yes Rotating Thermal+Optical Cameras ($2,500) Stationary Thermal+Optical Cameras ($650) Surge Protection AC ($200 per meter/source) DC ($100) Serial ($100 per line) Ethernet ($100 per line) Weather Station None ($0)Rainwise PV75 (PoA Irradiance, Ambient Temp, Module Temp) ($1150)Sensecap S700 (PoA Irradiance, Global Irradiance, Ultrasonic Wind Speed/Direction, Ambient Temp, Module Temp, Pressure, Humidity, Rain) ($1450) Add Reference Cell ($625) Swap PoA Irradiance for Reference Cell ($425) Transformer Monitoring Temperature - no repressurization required ($450) Pressure - requires repressurization with N2 ($450) Hydrogen - requires repressurization with N2 ($6000) Prepay 5 years of cell data and monitoring Yes Upload Site and Electrical Plans (optional) Additional Details(optional) Upfront Price Ongoing annual cost after initial period